This web page refers to our older busTRACE 6.0 which is no longer shipping. Click here for details on our latest generation busTRACE software.

busTRACE 6.0 This WEB page comes from the busTRACE 6.0 User's Manual. (Table of Contents)

Previous Topic Next Topic
 

If you have added a CDB to your script, and the device returns inbound data (i.e. Inquiry, Read Buffer, Read Sector, etc.), you can create a node link to have the script branch if the returned data contains a specified value.

When you click on the Add Link toolbar option (on the Node Links page), you are given the option to Branch on CDB Data match . If you choose the option, the following dialog will appear:

Here you specify where in the returned data the expected data is. For example, in Inquiry data, the Peripheral Device Type field is stored in byte #0, bits 4-0. If you were interested in creating a node link for an Inquiry CDB that returns device type 5, you would use the following settings:

Start Byte: 0
Start Bit: 4
Stop Byte: 0
Stop Bit: 0

You would set the value for the branch as a value of 5.

By default, we use the "==" operator in Step 3 to perform the branch if the specified data matches exactly the specified value. If you prefer, you can choose from the drop down list option to use the !=, >, >=, <, or <= operator instead.

See Also: